Vulcan-Hart 1ER85D Fryer User Manual


 
— 13 —
Dispose
The controller can also be programmed to alert the operator to dispose of the shortening by counting
the number of times the shortening is filtered. When the filter count is the same as the programmed filter
count, DISPOSE is displayed in the window.
PROG 00 - Enter the number of filter counts you want the controller to count before giving a
dispose alert. To disable the dispose reminder, enter 99.
ACT 00 - Leave at 00 unless editing. This is the number of times the shortening has been filtered.
Turn power switch off and open the drain valve.
Discard the shortening into suitable discharge container.
Close the drain valve and fill the vat with shortening.
Turn power switch on.
Enter the programming mode, select the dispose parameter and reset the actual filter count to
zero. This will also reset the actual cook count to zero.
NOTE: The dispose prompt can only be reset by resetting the actual filter count or disabling the
parameter.
NOTE: The filter prompt takes precedence over dispose.
See Daily Filtering section in this manual for more information.
TEMPERATURE AND TIME PROGRAMMING
Temperature
1. Press
to enter program mode. PROGRAM is displayed in the window.
2. Press
to enter temperature mode. 000°F and TEMP are displayed in the window.
3. Press
through to enter desired fry temperature. The fry temperature is displayed in the
window.
4. Press
to exit the temperature mode. Press again to exit program mode completely.
Time
There are ten timers with advanced timing features on the ERC fryer for setting fry times on multiple
products.
Timers
through :
1. Press
and enter the program mode. PROGRAM is displayed in the window.
2. Press
. The LED's on timers through are lit and SELECT PRODUCT is displayed
in the window.
3. To select a timer, press one of the lit timer numbers; CK# 00:00 and TIME are displayed in the
window.