Vulcan-Hart 52397 Convection Oven User Manual


 
3
ANCHORING STEAMER (Without Legs)
1. Place steamer in the desired location on the
leveled counter top and mark four corners.
Remove the steamer and drill
1
/2" holes as
indicated in Fig. 1.
2. Apply a bead of RTV or other equivalent sealant
around the bottom perimeter edge of the steamer.
If anchoring the steamer, this bottom seal is
necessary to meet NSF requirements.
3. Set steamer on counter and bolt down securely
with
3
/8 - 16 bolts (not supplied).
STACKING KIT
Follow instructions in the stacking kit when installing
stacked convection steamers.
24"
20"
2"
27 1/2"
23 1/2"
Drill 1/2" holes through
counter top
Mark 4 corners on
counter top
PL-50819
Fig. 1
ELECTRICAL CONNECTION
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH APPLICABLE
PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE
DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT.
The wiring diagram is located on the right side panel as you face the steamer.
ELECTRICAL DATA
Total
KW
Volts / Hz / Ph
Kilowatts Per Phase
Rated Amps
Circuit Size
(Amps)
Fuse Size or
Circuit Breaker Size *
(Amps)
90°C Copper
Wire Size
3 Phase
Amps Per Line Wire
1 Phase
Amps
L1 - L2 L2 - L3 L1 - L3 L1 L2 L3
7.5 208 / 60 / 1
36
50
50 8
7.5 240 / 60 / 1
31
45
45 8
7.5 208 / 60 / 3
2.5 2.5 2.5 21 21 21
30
30 10
7.5 240 / 60 / 3
2.5 2.5 2.5 18 18 18
25
25 14
7.5 480 / 60 / 3
2.5 2.5 2.5 9 9 9
15
15 16
10 208 / 60 / 1
48
70
70 8
10 240 / 60 / 1
42
60
60 8
10 208 / 60 / 3
3.3 3.3 3.3 28 28 28
40
40 10
10 240 / 60 / 3
3.3 3.3 3.3 24 24 24
35
35 10
10 480 / 60 / 3
3.3 3.3 3.3 12 12 12
15
15 16
15 208 / 60 / 1
72
100
100 6
15 240 / 60 / 1
63
90
90 6
15 208 / 60 / 3
5 5 5 424242
60
60 8
15 240 / 60 / 3
5 5 5 363636
50
50 8
15 480 / 60 / 3
5 5 5 181818
25
25 14
* Dual Element Time-Delay Fuse or
Inverse Time Circuit Breaker
Circuit Size (Minimum) & Fuse / Circuit Breaker Size (Maximum) compiled in accordance with the National Electrical Code (ANSI/NFPA 70), 1993 Edition.