Vulcan-Hart 52423 Pasta Maker User Manual


 
23
REMOVAL OF HIGH LIMIT
1. Drain water from the cooker.
2. Open cooker door and disengage wire harness located below the control housing to the right
side of the cooker. (Fig. 28)
Fig. 28
3. Follow steps 1- 4 for Removal of Cooker Control Housing.
4. From inside cooker tank with a
1
4" socket, remove (2) screws and the bracketing piece holding the limit and
thermostat bulbs to the tank. (See Fig. 23)
5. With a
1
2" socket, loosen the (2) bolts holding the right hand burner to the burner mounting frame.
(Fig. 29)
Fig. 29