Vulcan-Hart C24EA3 480V PRO Electric Steamer User Manual


 
MODEL C24EA - WATER LEVEL CONTROL COMPONENTS
F25213 (May 2006)Page 27 of 52
5. Disconnect the drain and drain flush hoses from
the Tee located below the drain valve.
6. Remove the drain valve body from the steam
generator tank.
7. Separate the Tee and nipple from the drain
valve body.
8. Reassemble parts removed in reverse order.
Apply liquid pipe thread sealant to threads of
plumbing connections.
NOTE: If motorized drain valve is in the open
position when power is applied to the steamer with
the power switch on, drain valve will not close and fill
water will flow through the generator into the drain.
9. Verify On/Off switch is in the off position and the
motorized drain valve is closed before applying
power to steamer.
NOTE: When power is applied and power switch is
off steamer will enter a drain cycle.
10. Check steamer for proper operation and leaks
around drain valve.