Vulcan-Hart GPC12S Pasta Maker User Manual


 
– 12 –
THERMOSTAT
Controls temperature of water in tank. Temperature at "simmer"
setting i
s approximately 190°F (88°C); burners will cycle on and off.
At "boil" setting,
temperature is 212°F (100°C); the burners will
remain on 100% of the time.
POWER SWITCH
Turns electric power to the pasta cooker on or off.
ON position opens the combination gas valve which allows the
ignitor to light the pilot. This
will happen every time the power
switch is turned on.
OFF position shuts
off all gas to the burners and pilot.
INDICATOR LIGHTS:
ON When lit, electric power to the machine is on.
TROUBLE When lit, the electronic igniter has not been able to light the pilot.
HEATING When lit, burners are supplying heat, warming water in tank per
thermostat.
HIGH LIMIT When lit, there is not enough water in the tank; system has shut
down.
MANUAL FILL VALVES Model GPC12 has one hot water fill valve. Model GPC12S has one
hot water fill valve, and one cold water fill valve on the chill tank. Turn
fill valves counterclockwise to open and clockwise to close.
GAS VALVE (Fig. 9) Turns gas supply to the pasta cooker on or off.
Fig. 8
CONTROLS (Fig's. 8 & 9)
OFF
ON
P
O
W
E
R
HIGH LIMIT
TROUBLE
HEATING
PUSH TO
TIME
BASKET LIFT CONTROL
15 MIN. TIMER
0
1
2
3
4
6
7
10
11
15
9
8
12
13
5
14
TIMED BASKETLIFT
OPTION
PL-53524
OFF
OFF
HOT
ON
ON
P
O
W
E
R
HIGH LIMIT
TROUBLE
HEATING
B
O
I
L
S
I
M
M
E
R
B
O
I
L
S
I
M
M
E
R
PUSH TO
TIME
BASKET LIFT CONTROL
15 MIN. TIMER
0
1
2
3
4
6
7
10
11
15
9
8
12
13
5
14
TIMED BASKETLIFT
OPTION
OFF
COLD
ON
OFF
HOT
ON
Model GPC12 / GPC16 Model GPC12S / GPC16S