Vulcan-Hart GPC12S Pasta Maker User Manual


 
– 14 –
2. Connect the power cord to an appropriate grounded receptacle.
3. Turn the gas valve (located inside the cabinet door - see Fig. 9) to the ON position.
4. Push the power switch to the ON position. A "snapping" noise will be heard. This is the igniter
lighting the pilot.
If the pilot fails to light within 90 seconds, the ignition system will automatically shut down and
the TROUBLE light will illuminate.
a. Push the power switch to the OFF position.
b. Wait 5 minutes.
c. Repeat Steps 2 and 3.
If the pilot still fails to light, contact a qualified Vulcan-Hart service representative.
5. Make sure the tank is full of water.
6. Turn the thermostat control knob to the desired setting.
Turning the Pasta Cooker OFF
CAUTION: If you drain the tank at the end of the day, it is imperative that you turn off the pilot
by pushing the power switch to the OFF position.
1. Push the power switch to the OFF position.
2. Turn the gas valve to the OFF position to shut off all gas to the system.
Extended Shutdown
1. Push the power switch to the OFF position and unplug the pasta cooker.
2. Turn gas valve to OFF position.
3. Drain tank by opening the drain valve (Fig. 11) located inside the cabinet door.