Vulcan-Hart K60GL Hot Beverage Maker User Manual


 
10
GAS KETTLES
LOCATION
Position the kettle in its final location. Check that there are sufficient clearances for operating and
servicing the kettle, and for proper clearance of the cover when raised. Keep the kettle free and
clear from all combustible substances. Minimum clearance from combustible and non-combustible
construction is 2" (5.0 cm) at the rear and 6" (15.2 cm) at each side.
The kettle draw off valve should be located near a floor drain.
Do not obstruct the flow
of
air into and around the
kettle.
This air flow is necessary
for
proper combustion
of gases and for ventilation of the kettle. Provisions for ventilation and incoming air supply for the
equipment in the room must be in accordance with the National Fuel Gas Code ANSI Z223.1 (latest
edition).
Stationary Kettle
FLUE
"D"
"P"
GAS CONNECTION
"E"
1.6
[41]
ELEC CONNECTION
"M"
12.0
[305]
"F"
ADD 2" FOR
PLUG VALVE
5.2[132]
"J"
GAS
CONNECTION
"N"
12.0
[305]
DRAIN TROUGH
ADD 2" FOR OPEN POSITION
8.0 FOR 3" DOV. ADD 3" FOR OPEN POSITION
"A"
"C"
"B"
"H"
7.6
[192]
"K"
"G"
"L"
= FLOOR DRAIN FOR DRAW-OFF VALVE
MODEL
TRUE
WORKING
CAPACITY
A
B
C
D
E
F
G
H
J
K
L
M
N
P
K20GL
20 gallons
21.6
In.
15.2
In.
36.8
In.
32.7
In.
18.6
In.
15.6
In.
19.5
In.
6.4
In.
17.0
In.
32.6
In.
19.2
In.
20.9
In.
8.3
In.
14.6
In.
76 liters
549
mm
386
mm
935
mm
831
mm
472
mm
396
mm
495
mm
163
mm
432
mm
828
mm
488
mm
531
mm
211
mm
371
mm
K40GL
40 gallons
26
In.
21.2
In.
39.2
In.
36.7
In.
19.8
In.
17.8
In.
16.0
In.
6.4
In.
18.0
In.
69.0
In.
15.6
In.
23.0
In.
11.6
In.
14.1
In.
152 liters
660
mm
538
mm
996
mm
932
mm
503
mm
451
mm
406
mm
163
mm
457
mm
1753
mm
396
mm
584
mm
295
mm
358
mm
K60GL
60 gallons
29.5
In.
24.2
In.
39.5
In.
40.9
In.
21.7
In.
19.8
In.
16.6
In.
6.0
In.
19.9
In.
76.6
In.
16.2
In.
26.5
In.
13.8
In.
13.7
In.
227 liters
749
mm
615
mm
1003
mm
1039
mm
551
mm
502
mm
422
mm
152
mm
505
mm
1946
mm
411
mm
673
mm
351
mm
348
mm