Vulcan-Hart ML-136057 Electric Steamer User Manual


 
— 15 —
C24GA SERIES GAS CONVECTION STEAMERS
The steamer and its parts
are hot. Use care when operating, clean-
ing or servicing the steamer.
Water Treatment System
A water treatment system is recommended for
steamers. Refer to your supplier’s manual for
normal maintenance procedures for proper
scale-free operation recommendations.
Scale Related Maintenance
Periodic maintenance is necessary to keep
your generator clean and efficient. Initially, after
three months of steamer usage, it is
recommended that you have your Vulcan-Hart
authorized servicer inspect the generator. Local
water conditions and steamer usage will
determine the frequency that this service must
be repeated; however, a minimum
recommendation is once a year. This
maintenance is not covered by warranty.
MAINTENANCE
Draining Generator
At least once daily, turn the unit off with the
power switch located on bottom cooking cavity,
to drain the generator.
Note: DO NOT remove the electric supply
or the unit will not drain.
Door Gaskets
If the door gasket is leaking due to a nick or cut,
it must be replaced. Damage to the gasket
sealing surface will cause steam leakage.
Flue
Annually (at minimum), when the steamer is
cool, check the flue and clear any obstructions.