Standard Oven With Standing Pilot (Fig. 2)
1. Turn Thermostat and Shut-off Valve to the OFF position.
2. Wait 5 minutes.
3. Remove lower panel.
4. Depress Red Button on safety valve and light pilot through
observation hole.
5. Hold down Red Button for at least 30 seconds.
6. When button is released, pilot should remain lit. Pilot
flame may be adjusted with screw on pilot adjustment
valve on pilot supply tubing located behind the control
panel. There should be only a slight amount of yellow in
the properly adjusted pilot flame.
7. Replace lower panel.
8. Turn Shut-off Valve to the ON position and turn the
Thermostat to the desired temperature.
9. If pilot flame becomes extinguished, repeat the above
procedure.
10. For a complete shutdown, turn the Thermostat, Shut-off
Valve, and gas shut-off valve to the OFF position.
Standard Oven with Electric Ignition (Fig. 3)
1. Turn Thermostat and Shut-off Valve to OFF position.
Wait 5 minutes.
2. Turn Shut-off Valve to ON position.
3. Turn Thermostat to desired setting.
4. Oven burner lights automatically.
5. For a complete shutdown, turn the Thermostat, Shut-off
Valve, and gas shut-off valve to the OFF position.
SHUT-OFF
VALVE
THERMOSTAT
RED BUTTON
(SAFETY)
PL-53512
Fig. 2
SHUT-OFF
VALVE
THERMOSTAT
PL-53513
Fig. 3