STANDARD OVEN PILOT SAFETY VALVE CHECK,
REPLACEMENT (Cont.)
3. Disconnect right- and left-hand pilot gas tubing from the safety valve (Fig. 39).
4. Disconnect right- and left-hand burner gas tubing from the safety valve (Fig. 40).
5. Remove safety valve from unit.
6. Install new valve by reversing Steps 1 through 4.
Fig. 40