Vulcan-Hart ML-126853 Electric Steamer User Manual


 
VHX SERIES STEAMERS - REMOVAL AND REPLACEMENT OF PARTS
F25154 (February 2004) Page 14 of 48
3. To install:
A. On the two replacement descalers, stretch
the coiled wire (cathode) at the top to
elongate the wire then form an open loop.
B. Hang the descalers on the front horizontal
support rod; one to the left of the heating
elements and one to the right.
C. Position the descalers so the core (anode)
is below the minimum water level in the
boiler and hanging freely.
NOTE: To function properly, the descalers must
not contact the interior surfaces of the boiler or
the heating elements.
COOKING COMPARTMENT
DOOR(S)
Removal
1. Remove top cover.
2. Open the door.
3. Pull hinge rod up.
4. Reverse the procedure to install, making sure
the door bushings are in place.
Gasket
1. Open the door.
2. Remove screws from the gasket plate.
3. Pull the gasket plate out from the door housing
and remove the gasket.
4. Position the new gasket on the gasket plate and
reverse the procedure to install.
5. Adjust the door as outlined in DOOR SEALING
ADJUSTMENT under COOKING
COMPARTMENT.
NOTE: Do not over tighten gasket plate screws as
this will compress the gasket excessively and
interfere with proper door sealing.
NOTE: Damage to the gasket sealing surface, such
as nicks or cuts, will cause steam leakage.
Handle
1. Open the door.
2. Remove screws from the top and bottom of the
door.
3. Pull the inner door panel out from the door
housing with the gasket plate and gasket still
attached.