VHX SERIES STEAMER - TROUBLESHOOTING
F25154 (February 2004)Page 45 of 48
COOKING COMPARTMENT CONTROLS
SYMPTOM POSSIBLE CAUSES
Cooking compartments do not operate. 1. No power to cooking compartment controls.
2. Pressure in boiler is below compartment pressure switch
setting.
3. Manual intake shutoff valve in the off position.
4. Door switch malfunction.
5. Timer malfunction.
6. Malfunctioning pressure switch in compartment.
7. Interconnecting wiring malfunction.
Steam generated inside compartment
when timer is off.
1. Steam supply solenoid not fully closing (clogged or dirty).
2. Timer contacts 1 & 3 closed.
Timer motor does not run. 1. Door open or door switch malfunction.
2. Timer not receiving power or malfunction.
Door not closing properly. 1. Door latch assembly malfunction or out of adjustment.
2. Striker adjustment.
Door won’t open. 1. Latch won’t release.
Buzzer not operating. 1. Timer malfunction.
2. Buzzer malfunction.
Compartment leaks water around door or
water accumulating in compartment .
1. Compartment drain screen clogged.
2. Door out of adjustment.
3. Drain line obstructed or not to an open air gap drain.
4. Worn or damaged door gasket.
5. Steamer not level.
Steam leaks around door. 1. Door out of adjustment.
2. Worn or damaged door gasket.
3. Drain line obstructed or not to an open drain.