Vulcan-Hart VEX Range User Manual


 
10
220/380, 240/415 VOLT VS/VM RANGES AND VR RANGES WITH OVEN
3 PHASE LOAD NOMINAL AMPS PER LINE WIRE
TOTAL KW PER PHASE 240/415 VOLT
KW 3 PHASE 1 PHASE
MODEL CONN. X-N Y-N Z-N X Y Z X Z
VR1,2,5 21.7 7.7 5 9 32 21 38 32 58
VR1,2,5 / VB73 27.7 10.7 8 9 45 33 38 45 71
VS,VM1,2,5 15 5 5 5 21 21 21 21 42
VS,VM1,2,5 / VB73 21 8 8 5 33 33 21 33 54
VR3,6,7 20.7 6.7 5 9 28 31 38 28 59
VR3,6,7 / VB73 26.7 9.7 8 9 41 33 38 41 71
VS,VM3,6,7 14 4 5 5 17 21 21 17 42
VS,VM3,6,7 / VB73 20 7 8 5 29 33 21 29 54
VR4 18.7 6.7 4 8 28 17 33 28 50
VR4 / VB73 24.7 9.7 7 8 41 29 33 41 62
VS,VM4 12 4 4 4 17 17 17 17 34
VS,VM4 / VB73 18 7 7 4 29 29 17 29 46
VOLTAGE FROM ANY PHASE TO NEUTRAL NOT TO EXCEED 250 VOLTS
220/380, 240/415 VOLT VRC RANGES WITH CONVECTION OVEN
3 PHASE LOAD NOMINAL AMPS PER LINE WIRE
TOTAL KW PER PHASE 3 PHASE 1 PHASE
KW 220/380V 240/415V
MODEL CONN. X-N Y-N Z-N X Y Z X Y Z X Z
VR1C,2C,5C 22 6.2 6.2 9.6 33 25 33 34 26 34 34 60
VR1C,2C,5C/VB73 28 9.2 9.2 9.6 40 38 40 41 39 41 41 80
VR3C,6C,7C 21 6.2 6.2 8.6 31 23 33 32 24 34 32 58
VR3C,6C,7C/VB73 27 9.2 9.2 8.6 37 35 38 38 37 39 38 76
VR4C 19 5.2 5.2 8.6 31 21 33 32 22 34 32 56
VR4C/VB73 25 8.2 8.2 8.6 37 33 38 38 34 39 38 73
VOLTAGE FROM ANY PHASE TO NEUTRAL NOT TO EXCEED 250 VOLTS
220/380, 240/415 VOLT VEX AND VMX RANGES WITHOUT OVEN
NOMINAL AMPS PER LINE WIRE LOAD
TOTAL KW 1PH,3-WIRE 2-WIRE 1PH,3-WIRE 2-WIRE KW/PHASE
CONN. 220/380 220 240/415 240 1 PHASE
MODEL 220/380 240/415 L1 L2 L1 L1 L2 L1 L1-N L2-N
VEX,VMX1 4.2 5 9.6 9.6 19.3 10.5 24 21 2.5 2.5
VEX2,VMX2 4.2 5 19.3 19.3 21 21
VEX3,VMX3 3.4 4 7.8 7.8 15.6 8.5 19 17 2.0 2.0
"VB73" in above charts denotes an electric elevated broiler installed over the range.