Vulcan-Hart VEX Range User Manual


 
9
ELECTRICAL DATA CHARTS
VR RANGES WITH STANDARD OVENS OR VS RANGES WITH CABINET BODY
"N/A" RANGES NOT AVAILABLE 480 VOLT
3 PHASE LOAD NOMINAL AMPS PER LINE WIRE
TOTAL KW PER PHASE 3 PHASE 1 PHASE
KW 208V 240V 480V 208V 240V 480V 208V 240V 480V
MODEL CONN. X-Y Y-Z X-Z X Y Z X Y Z X Y Z XYZ XYZ XYZ
VR1,2,5 21.7 7.7 5 9 70 53 58 60 46 51 30 23 25 104 90 45
VR1,2,5 / VB73 27.7 10.7 8 82 78 71 71 68 61 133 115
VS,VM1,2,5 15 5 5 5 42 42 42 36 36 36 18 18 18 72 63 31
VS,VM1,2,5 / VB73 21 8 8 —546754475847———10188—
VR3,6,7 20.7 7.7 5 8 65 53 54 57 46 47 28 23 24 99 86 43
VR3,6,7 / VB73 26.7 10.7 8 78 78 67 68 68 58 128 111
VS,VM3,6,7 14 5 5 4 38 42 38 33 36 33 16 18 16 67 58 29
VS,VM3,6,7 / VB73 20 8 8 —506750435843———9683—
VR4 18.7 6.7 4 8 61 45 50 53 39 43 19 27 22 90 78 39
VR4 / VB73 24.7 9.7 7 8 74 70 63 64 60 54 27 30 33 119 103 N/A
VS,VM4 12 4 4 4 33 33 33 29 29 29 14 14 14 58 50 25
VS,VM4 / VB73 18 7 7 —465846405140———8775—
480 Volt Only:
VR1,2,5 / VB73 21.7 7.7 11 9 ——————303436——N/A
VR3,6,7 / VB73 26.7 7.7 11 8 ——————283434——N/A
VS,VM1,2,5 / VB73 21 5115 ——————182929——44
VS,VM3,6,7 / VB73 20 5114 ——————162927——42
VR4 / VB73 24.7 6.7 10 8 ——————273033——N/A
VS,VM4 / VB73 18 4104 ——————142525——38
VR RANGES WITH CONVECTION OVENS
3 PHASE LOAD NOMINAL AMPS PER LINE WIRE
TOTAL KW PER PHASE 3 PHASE 1 PHASE
KW
208V,240V & 480V
208V 240V 480V 208V 240V
MODEL CONN. X-Y Y-Z X-Z X Y Z X Y Z X Y Z XYZ XYZ
VR1C,2C,5C 22 6.2 6.2 9.6 66 51 66 57 45 57 29 22 29 106 92
VR1C,2C,5C/VB73 28 9.2 9.2 9.6 78 76 78 68 66 68 34 33 34 135 117
VR3C,6C,7C 21 6.2 6.2 8.6 62 51 62 54 45 54 27 22 27 101 87
VR3C,6C,7C/VB73 27 9.2 9.2 8.6 74 76 74 64 66 64 32 33 32 130 112
VR4C 19 5.2 5.2 8.6 58 43 58 50 37 50 25 19 25 91 79
VR4C/VB73 25 8.2 8.2 8.6 70 68 70 61 59 61 30 29 30 120 104
VEX AND VMX RANGES
3 PHASE LOAD NOMINAL AMPS PER LINE WIRE
TOTAL KW PER PHASE 3 PHASE 1 PHASE
KW 208V 240V 480V 208V 240V 480V 208V 240V 480V
MODEL CONN. X-Y Y-Z X-Z X Y Z X Y Z X Y Z XYZ XYZ XYZ
VEX,VMX1 5 2.5 2.5 11 21 11 9 18 9 4.5 9.0 4.5 24 21 10.4
VEX2,VMX2 5 ————————————242110.4
VEX3,VMX3 4 2 2 8 17 8 7 14 7 3.6 7.2 3.6 19 17 8.3
"VB73" in above charts denotes an electric elevated broiler installed over the range.