Vulcan-Hart VHX24E5 Electric Steamer User Manual


 
VHX SERIES STEAMERS - REMOVAL AND REPLACEMENT OF PARTS
F25154 (February 2004)Page 11 of 48
HEATING ELEMENT MOUNTING
PLATE
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
1. Remove heating elements as outlined under
HEATING ELEMENTS.
2.
Loosen mounting hardware securing control
panel to frame and lower the panel.
3.
On models with cooking compartments
only,
disconnect power cord from power switch box
(rear of control panel).
4.
Disconnect pressure gauge tube
from fitting at
tee.
5.
Disconnect lead wire from Aux LLCO probe.
6.
Loosen both conduit locking nuts (1 1/2" & 3/8")
in main control box.
7. Loosen conduit nut (1 1/2") on elbow connected
to main control box.
8. Remove mounting bolts for main control box.
A. Lift main control box to remove from the
frame and position it to the left side.
9. Remove heating element mounting plate.
10. To install:
A.
Clean the mating surfaces on heating
element mounting plate and boiler.
B. Install new gasket on boiler side of
mounting flange.