Weber 43176 Water Dispenser User Manual


 
4
WWW.WEBER.COM
®
1
1b b
a
c
1
BUILT-IN CUTOUT DIMENSIONS
S-440, S-640
1
24” (610 mm) minimum*
a LP Tank Cabinet
b Any Surface
c Non-Combustable Surface
TANK CABINET CUTOUT DIMENSIONS
S-440 TOLERANCES
A 20
3
/
4
˝ (527.05 mm) +
1
/
4
˝ -
1
/
4
˝ (6.35mm)
B 27
1
/
2
˝ (698.5 mm) +
1
/
4
˝ -
1
/
4
˝ (6.35mm)
C 14˝ (355.6 mm) +
1
/
4
˝ -
1
/
4
˝ (6.35mm )
LOCATING YOUR LP TANK CABINET
When determining a suitable location for your LP Tank Cabinet installation, give attention
to concerns such as exposure to wind, proximity to traffic paths, and keeping any
gas supply lines as short as possible. Never locate the Summit
®
LP Tank Cabinet in
a garage, breezeway, shed, under an unprotected overhang, or other enclosed area.
Locate the LP Tank Cabinet and structure so there is enough room to safely evacuate
the area in case of a fire.
CLEARANCE FROM COMBUSTIBLE SURFACES OR STRUCTURES
ƽWARNING: Clearance from the outside walls of the sides
and back of the LP Tank Cabinet must be a minimum of 24
inches (610 mm) from any surface. Refer to “Typical Gas Supply
Installation” before starting installation.
ƽWARNING: The structure, “island” counter tops and adjacent
work areas for the LP Tank Cabinet installation must be built
from noncombustible materials only.
NOTE: If you have questions on what materials are
considered noncombustible, contact your local building
supplier or fire department.
BUILT-IN STRUCTURE CUTOUT DIMENSIONS
All dimensions are to finished surfaces.
ƽWARNING: All counter top finished surfaces must be
constructed of a noncombustible material.
GAS INSTRUCTIONS