ELECTRICAL INSTALLATION
Refer to the nameplate on the front of the fryer. Verify ELECTRICAL
SERVICE POWER. Voltage and phase must match the nameplate
specifications, and available electrical service amperage must meet or
exceed the specifications listed on page 1 of this manual.
Wiring must be no less than12 ga. solid copper wire, rated for at
least 75ºC.
Wire gauge, insulation type and temperature rating , as well
as type, size and construction of conduit, must meet or exceed
applicable specifications of local codes and of the National
Electrical Code.
Fryers are shipped from the factory wired for 3Ø electrical service.
Refer to the three-phase wiring diagram included with this fryer, and
verify that field wiring conforms to this diagram .
NOTE: 30# FRYERS are FIELD CONVERTIBLE to 1Ø.
If single-phase operation is required, refer to the 3-phase to 1-phase
Instructions included with the FRYER, and verify that both internal
wiring and field wiring conform to the included single-phase wiring
diagram.
INSTALLATION (continued)
7
WARNING
SHOCK HAZARD
Electrical connections must
be made by a licensed
electrician.
CAUTION:
SHOCK HAZARD
The ground lug of this
appliance must be connected
to a suitable building ground.
IMPORTANT:
WVAE-55F and WVAE-55FS
units MUST NOT BE
CONVERTED TO SINGLE
PHASE OPERATION.
Conversion of these units to
single phase operation
invalidates the UL listing and
will void the warranty.
IMPORTANT:
Contact a licensed electrician
to install and connect
electrical power to the
appliance.
IMPORTANT:
Damage due to being
connected to the wrong
voltage or phase is NOT
covered by warranty.
M381 301603 OpM (Supplemental) NFPA Hood