Westinghouse GEK1235W Cooktop User Manual


 
25
INSTALLING
Operation on SNG
If the cooker is to be used with SNG, then the grill
burner MUST be modified by the replacement of the
shutter which fits into the throat of the grill burner.
You can buy the kit for this modification from your
nearest spare parts stockist. (refer to rear cover for
contact details.)
1. Remove the control panel. Remove the existing
NG shutter securing screws (as in diagram) and
slide upwards to disengage from grill burner.
2. Slide the SNG shutter into position and secure
with screws.
Grill Shutter
Operation on Propane
An inlet fitting with pressure test point is provided.
Orient the fitting so that gas flows in the direction of the
arrow marked on the fitting. Use the sealing washer to
connect the fitting to the flexible hose. Connect the gas
supply to the 1/2” BSP internal thread inlet of the fitting.
Gas connection
Read these points before connecting to the gas supply:
The cooker inlet connection point is the inlet to the
regulator or LP test point adaptor. This connects to the
flexible hose fitted to the appliance. The appliance
must be installed using the hose supplied.
The regulator/inlet connection must be accessible
when the appliance is installed.
Operation on NG/SNG
Read these points about operation on NG/SNG and look
carefully at the diagram:
The appliance regulator provided MUST be fitted and
positioned so that the pressure nipple is accessible.
The arrow showing the direction of the flow MUST be
pointed correctly.
Connect the gas supply to the 1/2” BSP internal thread
inlet of the regulator.
The flat fibre washer provided with the regulator MUST
be used when making the gas connection.
INSTALLING THE GAS COOKER
(continued)
WMAN_540 Upright_Jun11.indd 25 28/06/11 12:07 PM