INSTALLING
SAFETY WARNINGS ABOUT INSTALLATION
WARNING
The cooker MUST be installed and serviced by
a qualified technician.
A Certificate of Compliance MUST be supplied
to be kept by the customer.
The packing materials MUST be removed before
you install the cooker.
You MUST follow the installation instructions in this booklet.
The surrounding kitchen cabinets MUST be able to
withstand 85°C. Electrolux Products WILL NOT accept
responsibility for damage caused by installation into
kitchen cabinets which cannot withstand 85°C.
The vents, openings and air spaces MUST NOT
be blocked.
You MUST NOT pull the cooker by the door handles
or the splashback.
The cooker MUST be checked every five years.
Locating the cooker
Study the diagrams below to be sure of the dimensions
required to locate the cooker safely.
Note: Make sure that the top of the hotplate surface is
at least 10 mm higher than the level of the benchtops.
TIPS & INFORMATION
Before you cook in your new oven it is important that
the protective oils used in the manufacture of the product
be removed.
Make sure that the room is well ventilated (to allow
smoke to escape).
Run the grill on high for 30 minutes, without grill dish.
Then run the oven on 180°C for 2 hours.
Wiring requirements
The cooker MUST be installed in compliance with
Wiring connections in AS/NZS 3000 Wiring Rules
Local regulations, municipal building codes and other
statutory regulations
Data plate gives information about rating
is located on the inside panel
of the grill door
Circuit diagram is located on the back panel
of the control panel
An all pole disconnect functional switch MUST be
provided near the appliance in an accessible position
(AS/NZS 3000 – Clause 4.7.1).
Wiring MUST be protected against mechanical failure
(AS/NZS 3000 – Clause 3.9).
A means of disconnection with a contact separation
of at least 3mm MUST be supplied in the fixed wiring.
Note: To gain access to the terminal block, remove the rear
panel by unscrewing the two assembly screws.
WARNING
When connections are made to a multi-phase 240V supply,
the bridge piece should be removed from between the
active connections.
INSTALLING THE ELECTRIC COOKER
WMAN_540 Upright_Jun11.indd 23 28/06/11 12:07 PM