Whirlpool ECKMF-6 Ice Maker User Manual


 
B. INSTALLING WATER VALVE ON
WER BACKOF CABlNET LEG
Bl.
Temporarily remove screws from right end of
lower back cover,lf present.
82. Insert water valve into receptacle terminals
completely so terminals are not exposed.
83. Fasten valve to right rear leg of the refrigerator
with two screws (#488649).
Cm INSTALLING WATER LINE BETWEEN INLET
TUBE (bp) AND WATER VALVE (battom)
488645
‘EP Cl
0
841707
b
836240
STEP
C2
Cl.
Remove plug from factory installed inlet tube on
back. Place one clamp (#488878) over the spout.
Put tube insert (#841707) in one end of tubing
that has been soaking in hot water. Put end of
tubing into spout. Tighten clamp with screw
(#488645).
C2. Place 2 clamps (#488366) over tubing. Remove
two upper sealing screws in back of cabinet and
throw away. Anchor clamps to cabinet with
screws (#488645). (If lower back cover is not
present or on bottom freezer refrigerator, use 1
clamp and
1
screw.)
C3.
Be sure that tube is clear of fan. Cut off extra