Whirlpool Range Range User Manual


 
GASCONVERSIONS
2. Unplug or disconnect power.
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
NOTE: Gas conversions (from natural gas to LP gas or from LP
gas to natural gas) must be done by a qualified person.
3. Open broiler door and remove broiler pan. The gas pressure
regulator is located in the back right hand corner of the broiler
compartment.
A.Gaspressureregulator
IMPORTANT: Do not remove the gas pressure regulator.
NOTE: Do not remove the spring beneath the cap.
4. Remove the cap from the gas pressure regulator using a flat-
blade screwdriver.
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti=tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
To Convert Gas Pressure Regulator
1. Ensure that the manual shutoff valve is in the closed position.
A
" ,........................................C
A. Shutoff valvein "closed" position
B. Gassupply line
C. Torange
12
Turn the cap over so that LP is visible.
A
A. Cap
6. Reinstall the cap.
To Convert Surface Burners
1. Remove burner grate, burner caps, and burners.
.......................................A
A. Burnercap
B.Burner