Whynter FM-62DZ Freezer User Manual


 
6
DC input power
When powering your portable freezer with a standard 12 V socket, the unit will
not work if socket has a voltage of less than 10.4 V. The unit will restart when the
voltage is 11.8V or greater.
When powering your portable freezer into a standard 24 V socket, the unit will
not work if the socket has a voltage of less than 22.5 V. The unit will restart when
the voltage is 24.2 V or greater.
Your portable freezer uses a digital control system for adjusting the thermostat.
1. SET:
Temperature setting:
Press the set button once to set desired temperature of the Small zone.
Press the set button twice to set desired temperature of the Large zone.
Battery cut-out voltage setting:
This function sets the minimum voltage that the unit will run. Press the set button
3 times to set the Battery cut-out voltage. To select different cut-out voltage (10V/
10.7V/ 11.8V), press the +/- buttons.
2. +: Button for increasing the temperature setting.
3. -: Button for decreasing the temperature setting.
4. ECO:
ECO button: Press the ECO button to set the unit in ECO mode. The unit
maintains the internal temperature at about 2F higher than the set temperature.
ECO light: Indicates when the ECO mode is on.
5. RUN light: When the RUN light is green, it indicates the unit is running.
6. Battery display: Shows battery condition in DC power supply only.
*When battery level is too low, the battery display will flash.
OPERATING YOUR
PORTABLE FREEZER
Test-Run
UNDERSTANDING THE TEMPERATURE CONTROL SETTING