Wolf C48(S Range User Manual


 
- 9 -
4. Turn the burner valve ON to the desired heat.
5. If burners fail to light, turn off all valves, and then call an authorized installation or service person.
6. To shut down, turn the burner valve to the OFF position.
7. For complete shut down, turn all burner valves to the OFF position. Turn off main gas supply.
Thermostatic Griddle
1. Turn the thermostat to the OFF position.
2. Turn the main gas supply valve to the ON position.
3. Depress and hold the red button on the safety valve and light the pilot through the slotted opening
in the manifold cover near the burner valve knob.
4. Hold red button down for at least 30 seconds.
5. When button is released, pilot should remain lit.
6. Pilot flame must be high enough to heat thermocouple.
7. Turn thermostat to desired temperature setting.
8. If ignition fails, turn the control knob to OFF. Wait 5 minutes and repeat the above procedure.
DO NOT attempt to relight pilot without waiting 5 minutes.
9. For temporary or nightly shutdown, turn control knob to OFF position.
10. For complete shutdown, turn control knob to OFF position, and turn off main gas supply.
OVEN SECTION
- Standard Oven with Standing Pilot, Convection Oven with Standing Pilot
1. Turn thermostat to OFF position.
2. Turn the main gas supply valve to the ON position.
3. Lift up on louvered kick panel and rotate down 90°.
4. Depress red button on safety valve and light pilot through opening in burner box area.
5. Hold red button down for at least 30 seconds.
6. When button is released, pilot should remain lit.
7. Pilot flame must be high enough to heat thermocouple.
8. Return louvered kick panel to original position.
9. Convection Oven – Turn on fan switch located between oven control knob and pilot safety valve.
10. Turn thermostat to desired temperature setting.