Wolf C60(S Range User Manual


 
FLUE CONNECTIONS
DO NOT obstruct the flow of flue gases from the flue located on the rear of the range. Proper venting
of flue gas is vital to the safe and efficient operation of the range. Problems arising from the intentional
obstruction of the flue will result in voiding of warranty. It is recommended that the flue gases be
ventilated to the outside of the building through a ventilation system installed by qualified personnel.
From the termination of the flue to the filters of the hood venting system, a minimum clearance of 18"
(457 mm) must be maintained. Information on the construction and installation of ventilating hoods
may be obtained from the standard for "Vapor Removal from Cooking Equipment," NFPA No. 96 (latest
edition), available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
ELECTRICAL CONNECTIONS
Electrical and grounding connections must comply with the applicable portions
of the National Electrical Code and/or other local electrical codes.
Disconnect the electrical power to the machine and follow Lockout / Tagout
procedures.
Appliances equipped with a flexible electrical supply cord are provided with a
three-prong grounding plug. It is imperative that this plug be connected into a properly
grounded three-prong receptacle. If the receptacle is not the proper grounding type, contact an
electrician. Do not remove the grounding prong from this plug.
The convection range is designed for 120 volt power supply and is provided with a flexible electric
supply cord and plug that must be plugged into the proper receptacle. Do not connect the convection
range to electrical supply until after gas connections have been made. The wiring diagram for the
convection range is located on the rear of the appliance.
OPERATION
The appliance and its parts are hot. Use care when operating, cleaning, or
servicing the appliance.
CONTROLS
Open Top Burner Valve — Allows gas to flow to the top burners. To open valve, turn knob
counterclockwise. To close valve, turn knob clockwise.
Manual Griddle Valve — Allows gas to flow to the griddle burners. To open valve, turn knob
counterclockwise. To close valve, turn knob clockwise.
Oven Thermostat — Regulates oven temperature. The thermostat temperature range is from LOW at
approximately 250°F (121°C) to HI at approximately 500°F (260°C). Turn the thermostat
counterclockwise to increase temperature and clockwise to decrease temperature. Oven temperature
regulation is the most accurate between 300°F (149°C) and 500°F (260°C).
- 7 -