8
WOLF COOKTOP LOW-PROFILE HOOD USE & CARE
HOOD CONTROLS
The Wolf cooktop low-profile hood is operated
using the touch control pads on the front face
of the hood. Refer to the illustration below.
L) LIGHTS.
Touch the pad once to turn the
lights ON, touch a second time to turn the
lights ON to a brighter level and touch a
third time to turn the lights OFF.
1)
A touch activates the blower motor at the
first speed (icon is illuminated). Press the
pad for about two seconds to turn the
blower OFF.
2)
Activates the blower at the second speed.
3)
Activates the blower at the third speed.
4)
Activates the blower at the fourth speed.
A)
Touch the pad to set a
TIMER
which keeps
the blower operating at the current speed
for 10 minutes.
F) FILTER.
After 30 hours of operation, the
icon is illuminated to indicate that the
grease filter(s) must be cleaned. After 120
hours, the icon flashes to indicate that the
grease filter(s) must be cleaned and the
charcoal filter replaced. To reset the hour
counter, touch
(F)
while the icon is
illuminated or flashing.
Hood controls
HEAT SENTRY THERMOSTAT
Your hood is equipped with a HEAT SENTRY™
thermostat. This thermostat is a device that
will turn on or increase the speed of the
blower if it senses excessive heat above the
cooking surface.
If the blower is OFF, it turns the blower ON
to HIGH speed.
If the blower is ON at a lower speed setting,
it increases the blower speed to HIGH.
When the temperature level drops to normal,
the blower will return to its original setting.
The HEAT SENTRY thermostat can start
the blower even if the hood is turned OFF.
When this occurs, it is impossible to turn
the blower OFF with its switch. If you
must stop the blower, do it from the main
electrical panel.