Planning Information
Model CTWH36 Cooktop Wall Hood
7
Dimensions in parentheses are in
millimeters unless otherwise specified.
DUCTING CONSIDERATIONS
Wolf cooktop wall hoods are shipped without
the blower assembly. Internal, in-line or remote
blower assemblies are available. For wall hoods,
the remote blower can be mounted on the roof
or an exterior wall.
IMPORTANT NOTE: Install these ventilation
hoods only with a Wolf blower.
Wolf cooktop wall hoods have an 8" (203) round
vertical discharge. Ducting for wall hoods can
run through the roof or an external wall as
shown in the illustration below.
Refer to the Cooktop ventilation charts at the
end of this section for recommendations and
blower options.
Ducting considerations
cooktop wall hoods.
WALL CAP
OR REMOTE BLOWER
COOKTOP
WALL HOOD
DUCTWORK INSTALLATION
THROUGH ROOF
DUCTWORK INSTALLATION
THROUGH WALL
8" (203) ROUND
VERTICAL DISCHARGE
8" (203) ROUND DUCT
CHIMNEY FLUE EXTENSION
TELESCOPIC CHIMNEY FLUE
8" (203) ROUND ELBOW
8" (203) ROUND DUCT
6
7
/8" (175) OR 9
1
/4" (235)
21"
(535)
24" TO 30"
(610–762)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
ROOF CAP OR REMOTE BLOWER –
TRANSITION FROM 8" (203) TO 10" (254) DUCT
REQUIRED FOR REMOTE BLOWER