This installation
must conform with
local codes and
ordinances.
INSTALL THE RANGETOP
Prepare the finished rough opening for the
rangetop according to the Installation Specifi-
cations illustration for your model on pages
9–11. The platform must be 19 mm thick and
include a cut-out at the right rear for gas
supply and electrical connections.
IMPORTANT NOTE:
The platform must be
level to ensure that the cooking surface is
level.
Remove and discard all packing materials,
including cardboard and tape on the outside of
the rangetop. Remove the burner grates and
styrofoam off the top cooking surface. Be
sure to remove the burner caps packaged in
styrofoam below the burner grates.
If your installation requires a riser, it must be
attached to the rangetop before installation.
Refer to the installation instructions packaged
with the riser.
Position the rangetop on the platform. Gas
supply and electrical connections should be
made before the rangetop is placed in its final
position.
IMPORTANT NOTE:
The sealed rangetop must
be connected to a regulated gas supply.
IMPORTANT NOTE:
This installation must
conform with local codes and ordinances.
The rating plate, located on the underside of
the burner box, has information on the type of
gas that should be used. If this information
does not agree with the type of gas available,
check with the local gas supplier.
An ISO 7-1 gas inlet thread is provided on all
units. Please contact your local Wolf dealer if
an ISO 228-1 or other gas inlet thread is
required. Pipe joint compounds, suitable for
use with LP gas should be used. LP gas suppli-
ers usually determine the size and materials
used on the system.
If local codes permit, a flexible metal appliance
connector is recommended for connecting this
sealed rangetop to the gas supply line. Do not
kink or damage the flexible connector when
moving the sealed rangetop. You will need to
determine the fittings required, depending on
the size of your gas supply line, flexible metal
connector and shut-off valve.
If rigid pipe is used as a gas supply line, a
combination of pipe fittings must be used to
obtain an in-line connection to the sealed
rangetop. All strains must be removed from
the supply and gas lines so the sealed
rangetop will be level and in line.
EXPLOSION HAZARD—
Securely tighten all external gas
connections.
Failure to do so can result in explosion,
fire or death.
GAS SUPPLY REQUIREMENTS