Wolf ICBSRT304 Cooktop User Manual


 
ISLAND | PENINSULA INSTALLATIONS
Minimum clearances to combustible
surfaces:
Island Installations: Minimum 305 mm
clearance to rear wall that rises above the
countertop.
Peninsula Installations: Minimum 152 mm
clearance to side walls and minimum
305 mm clearance to rear wall that rises
above the countertop.
Refer to the Installation Specifications
illustration for your model on pages 9–11
for the exact rough opening dimensions.
8
WOLF SEALED BURNER RANGETOP
MINIMUM CLEARANCES
IMPORTANT NOTE:
Caution must be used
in planning the proper installation of the Wolf
sealed burner rangetop to avoid fire or
damage to adjacent cabinetry or kitchen
equipment. Be sure to follow the minimum
clearances established in the finished rough
opening dimensions.
Refer to the Installation Specifications
illustration for your model on pages 9–11
for the exact rough opening dimensions.
WALL INSTALLATIONS
Minimum clearances to combustible
surfaces:
Minimum 457 mm clearance from bottom
of upper cabinet to countertop, within
152 mm minimum side clearance.
Minimum spacing between overhead side
cabinets must be greater than or equal to
the nominal width of the rangetop. The
maximum depth of overhead and side
cabinets is 330 mm, within 152 mm side
clearance.
0 mm clearance for adjacent combustible
materials below the countertop, both sides
and rear.
Bottom of ventilation hood must be
762 mm minimum to 914 mm maximum
from countertop.
Minimum clearances for sealed burner
rangetops without a ventilation hood:
Model ICBSRT304: 762 mm minimum
vertical distance from countertop to
combustible materials above the rangetop.
All Other Sealed Burner Rangetops:
Surface Burners or Griddle (G) Models:
914 mm minimum vertical distance from
countertop to combustible materials above
the rangetop.
Charbroiler (C) Models: 1118 mm minimum
vertical distance from countertop to
combustible materials above the rangetop.
Failure to locate the rangetop without
the proper clearances will result in a fire
hazard.
RISER REQUIREMENTS
Installations against a combustible surface:
Model ICBSRT304: No riser requirements.
914 mm Sealed Burner Rangetops: A
minimum 254 mm riser is required for all
charbroiler (C) or griddle (G) models
installed against a combustible surface.
1219 mm Sealed Burner Rangetops: A
minimum 254 mm riser is required for all
charbroiler (C) or griddle (G) models
installed against a combustible surface.