FULL SIZE GAS CONVECTION OVENS - SERVICE PROCEDURES AND ADJUSTMENTS
F32700 (February 2006) Page 24 of 64
DOOR ADJUSTMENT
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
1. Check the doors to make sure they have an
equal gap between them and that the vertical
edge of the door is parallel to the vertical door
seal. If the doors are not positioned in this
manner, adjust the doors as described.
2. Remove the top front cover.
3. Loosen the screws that secure the upper door
bearings and related hardware, just enough to
allow door movement.
4. Move the door until proper alignment is
achieved then tighten the screws on the upper
door bearing hardware.
5. Repeat step 3 and 4 on the opposite door, if
necessary.
DOOR CATCH BALL
ADJUSTMENT
(INDEPENDENT DOORS)
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
1. Remove top front cover as outline under
COVERS AND PANELS in REMOVAL AND
REPLACEMENT OF PARTS.
2. Open the doors and inspect door strike for
proper shape.
A. Replace if bent and adjust as outlined in
this procedure.
3. Open and close the doors several times while
observing the catch ball operation.
A. Replace if malfunctioning and adjust as
outlined in this procedure.
NOTE: Shims may be required under the
door strike, before the proper door tension
adjustment can be set.