Wolf WKG 126620 Convection Oven User Manual


 
FULL SIZE GAS CONVECTION OVENS - CONDENSED SPARE PARTS LIST
CODE & PROBLEM PROBABLE CAUSE SOLUTION
F32700 (February 2006) Printed in U.S.A.
Er06 - Zone 1 A/D underflow
error
Incorrect sensor type
Measuring temperature outside the
sensor range
Check the InP1 setup parameter.
Verify it matches your sensor.
Check sensor and connections for a
reversed or open sensor. If the
condition causing the error is
resolved, the error will clear.
Er07 - Zone 1 A/D overflow
error
Open sensor Check the InP1 setup parameter.
Verify it matches your sensor.
Check sensor and connections for a
reversed or open sensor. If the
condition causing the error is
resolved, the error will clear.
Er10 - Stack overflow error Microprocessor malfunction Cycle power.
Check sensor and connections for a
reversed or open sensor.
Er11 - Open sensor error Open sensor Check the InP1 setup parameter.
Verify it matches your sensor.
Check sensor and connections for a
reversed or open sensor.
Er12 - Shorted sensor Incorrect sensor type
Measuring temperature outside the
sensor range
Check the InP1 setup parameter.
Verify it matches your sensor.
Check sensor and connections for a
reversed or open sensor.
CONDENSED SPARE PARTS LIST
WKG SERIES
Part No. Description
340324-8 Main Power Switch (On/Off/Oven Cool)
411506-3 Thermostat, KX (WKG, WKGX)
353613-2 Temperature Control Board (WKGD, WKGDX)
353589-1 Temperature Probe (WKGD, WKGDX)
411496-F1 Door Switch
497269-1 Gas Valve, Natural
497269-2 Gas Valve, Propane
427137-2 Ignition Module
416535-6 Heat Relay
346357-1 High Limit Thermostat
424194-1 Igniter/Flame Sensor
411690-1 Timer - 60 Minute
340324-9 Light Switch, Roast & Hold or Fan Speed
358516-1 Blower Motor, 2Sp. 120 Volt
424846-1 Computer Control (WKGC, WKGCX)
920883-3 Temperature Probe (WKGC, WKGCX)
821875-2 SST Relay (WKGD, WKGDX)
421758-G1 Transformer