F. The stop cable must be positioned where it
moves freely and does not get pinched.
3. Position door chain assembly to factory setting
if the conditions in step 2 are not met.
4. If right door does not lead the left door in
closing:
A. Loosen locknut on both turnbuckles.
B. Loosen left turnbuckle.
C. Tighten right turnbuckle.
D. Tighten locknut on both turnbuckles.
5. If the right door leads the left door by more than
3/8 inch:
A. Loosen locknut on both turnbuckles.
B. Loosen right turnbuckle.
C. Tighten left turnbuckle.
D. Tighten locknut on both turnbuckles.
6. Check doors for proper operation.
NOTE: The locknuts must be tight during testing or
the adjustment will not hold.
A. If doors do not close properly, repeat step
4, 5 and 6.
B. If doors operate properly, continue with
procedure.
7. Install the lower front cover.
COMPUTER CONTROL
(WKGC/WKGCX)
Operation
Refer to the Owner's Manual for specific operating
instructions.
Setup Mode
NOTE: Use the setup mode to verify that the control
is configured to the factory settings which result in
the proper operation of the oven. If the CAL1
parameter is other than zero, determine if it is still
needed before resetting to zero. See COMPUTER
CONTROL CALIBRATION (WKGC/WKGCX).
CAUTION: Changing the C_F, InP1, rL1 & rH1
parameters will default all menus.
1. Use this key sequence to access the setup
mode.
Up arrow; Rack 1; Temperature; Temperature;
Down arrow; Rack 1
2. Once in the setup mode the display will
alternate between the parameter and
programmed data.
To change data to the factory setting, use
the arrow keys.
To select the next parameter, press the
Rack 1 key.
After the last Parameter and Data is
viewed, press the Rack 1 key a final time
to exit the setup mode and return to
operations mode. The current set point
temperature will be displayed.
After 1 minute of no key activations, the
control will return to operation mode.
3. Listed are the parameters and data you should
find.