Zanussi ZBF 760 Oven User Manual


 
20
Electrical Connection
Technical Data
We strongly recommend that all operations
for the installation of your cooker be carried
out by QUALIFIED PERSONNEL to the
relevant British Standards.
The oven is designed to be connected to 240V (50Hz)
electricity supply.
The oven has an easily accessible terminal block
which is marked as follows:
Letter L - Live terminal
Letter N - Neutral terminal
- Earth terminal
THIS APPLIANCE MUST BE EARTHED
The cable used to connect the oven to the electrical
supply must comply to the specifications given
below.
Models Rating Cable cross Fuse
section mm
2
and
Type of the cable min.
ZBF 760
2570 W 2,5 mm
2
Ho5 RR-F 13 A
For Europe use only
Models Rating Cable cross Fuse
section mm
2
and
Type of the cable min.
ZBF 760
2570 W 6 mm
2
6242 Y 15 A
For Uk use only
It is necessary that you install a double pole switch
between the appliance and the electricity supply
(mains), with a minimum gap of 3mm between the
switch contacts and of a type suitable for the required
load in compliance with the current rules.
The switch must not break the yellow and green earth
cable at any point.
Important
After installation and connecting, the cable must be
placed so that it cannot at any point reach a tempera-
ture of more than 50°C above the ambient temperatu-
re.
Before the appliance is connected, check that the
main fuse and the domestic installation can support
the load; and that the power supply is properly
earthed.
The manufacturer disclaims any responsibility should
these safety measures not be carried out.
DIMENSIONS Height 580 mm.
OF RECESS Width 560-570 mm.
Depth 550 mm.
DIMENSIONS Height 320 mm.
OF THE Width 420 mm.
OVEN CAVITY Depth 390 mm.
Oven capacity 53.2 litres
Heating elements rating
Oven element 2.5 kW
Grill element 1.8 kW
Convenction Fan 30 W
Oven Light 15 W
Cooling Fan 25 W