26
Electrical Connection
The oven is designed to be connected to 230-240V
(50Hz) electricity supply.
The oven has an easily accessible terminal block
which is marked as follows:
Letter L - Live terminal
Letter N - Neutral terminal
or E - Earth terminal
THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the electrical
supply must comply to the specifications given below.
It is necessary that you install a double pole switch
between the oven and the electricity supply (mains),
with a minimum gap of 3mm between the switch
contacts and of a type suitable for the required load in
compliance with the current rules.
The switch must not break the yellow and green earth
cable at any point.
Important
After installation and connecting, the cable must be
placed so that it cannot at any point reach a tempera-
ture of more than 60°C above the ambient temperature.
Before the oven is connected, check that the main
fuse and the domestic installation can support the
load; and that the power supply is properly earthed.
The manufacturer disclaims any responsibility should
these safety measures not be carried out.
DIMENSIONS Height 580 mm.
OF RECESS Width 560-570 mm.
Depth 550 mm.
DIMENSIONS Height 320 mm.
OF THE Width 420 mm.
OVEN CAVITY Depth 390 mm.
Oven capacity 53.2 litres
Heating elements rating
Oven element 1.89 kW
Top element 0.834 kW
Bottom element 1.055 kW
Convection element 2.08 kW
Grill element 1.82 kW
Double Grill element 2.655 kW
Pizza Oven Function 3.135 kW
Convection Fan 30 W
Oven Light 15 W
Cooling Fan 25 W
Total Rating 3.200 kW
This oven must be installed by qualified
personnel to the relevant British Standards.
Technical Data
The oven must be installed according to the
instructions supplied.
Installation
Connection Min. size Cable / flex Fuse
via Cable/flex type
Cooker 6 mm
2
PVC/PVC 20 A
Control twin and
Circuit earth
For Uk use only
For Europe use only
Min. size Cable/flex Cable / flex type Fuse
2.5 mm
2
H05 RR-F 15 A