Zanussi ZCM 7902 Range User Manual


 
32
CONNECTING TO THE ELECTRICITY SUPPLY
Warning: This appliance must be earthed.
Do not earth this appliance to the gas supply piping.
· We recommend you use a new length of 6mm
2
twin core and earthed cable to ensure your safety.
· Make connection as shown in Fig 2 by proceeding as follows:-
· Preform wires to the appropriate shape to suit fitting into the mains terminal block.
· Strip inner insulation on wires using wire strippers.
· Twist the bared wires using pliers.
· Cut bared wires 10mm away from the end of the inner insulation. Where uninsulated Earth wires are used
ensure they are suitably sheathed to leave 10mm bare wire to fit into the terminal.
· Clamp bare wires into the relevant terminal (Fig. 2) and check they are held by tugging each one in turn.
· Clamp the mains cable securely ensuring 5mm of the outer insuation is inside the terminal block and that the
wires are not taught but not so slack as to cause any fouling.
· Connect the remaining end of the mains cable to the appliance to the appliance point / junction box.
· Place fuse / miniature circuit breaker in circuit and switch on at mains.
NOTE: HOUSE CIRCUIT
Earth leakage / continuity tests must be carried out before the appliance is connected to the mains supply and re-
checked after fitting.
INSTALLATION INSTRUCTIONS
FIG.2.