DIMENSIONS Height 878 mm.
OF RECESS Width 560-570 mm.
Depth 550 mm.
DIMENSIONS Height 320 mm.
OF THE Width 420 mm.
MAIN OVEN Depth 390 mm.
CAVITY Oven capacity 53.2 litres
DIMENSIONS Height 185 mm.
OF THE Width 420 mm.
LOWER OVEN Depth 400 mm.
CAVITY Oven capacity 31 litres
Upper oven ratings
Fan Oven element 2.08 kW
Grill element 1.82 kW
Convection Fan 30 W
Oven Light 15 W
Cooling Fan 25 W
Total Rating 2.15 kW
Lower oven ratings
Oven element (top+bottom) 1.89 kW
Grill element 1.82 kW
Oven Light 15 W
Total Rating 1.93 kW
Total connected load 4.055 kW
Electrical Connection
The oven is designed to be connected to 230-240V
(50Hz) electricity supply.
The oven has an easily accessible terminal block
which is marked as follows:
Letter L - Live terminal
Letter N - Neutral terminal
or E - Earth terminal
THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the electrical
supply must comply to the specifications given
below.
It is necessary that you install a double pole switch
between the oven and the electricity supply (mains),
with a minimum gap of 3mm between the switch
contacts and of a type suitable for the required load
in compliance with the current rules.
The switch must not break the yellow and green
earth cable at any point.
Important
After installation and connecting, the cable must be
placed so that it cannot at any point reach a tempe-
rature of more than 60°C above the ambient tem-
perature.
Before the oven is connected, check that the main
fuse and the domestic installation can support the
load; and that the power supply is properly earthed.
The manufacturer declines any responsibility should
these safety measures not be carried out.
This oven must be installed by
qualified personnel to the relevant
British Standards.
The oven must be installed according to
the instructions supplied.
Installation
Connection Min. size Cable/flex Fuse
via Cable/flex type
Cooker 6 mm
2
PVC/PVC 30 A
Control twin and
Circuit earth
For Uk use only
For Europe use only
Min.size Cable/flex Cable / flex type Fuse
4 mm
2
H05 RR-F 30 A