Zanussi ZEL 640 Cooktop User Manual


 
15
similar characteristics: H05 V2V2-F. The
cable has three wires. The earth wire is
yellow/green and must be approx. 2 cm
longer than the phase and neutral wires
(Figure). Fit the cable with a plug
suitable for the load and connect it to a
suitable safety socket.
To connect directly to the mains, a
suitable omnipolar switch complying
with current standards and with a
contact gap of at least 3 mm must be
installed between the appliance and the
electrical system.
The yellow/green earth wire must not
be interrupted by the switch. The brown
phase wire (coming from terminal "L" on
the terminal block) must always be
connected to the power supply phase.
In any case the power cable must be
positioned in such a way that no part of
it reaches a temperature of 50°C higher
than the ambient temperature.
The cable is guided by means of
clamps fixed to the side of the cabinet,
in order to avoid any contact with the
equipment beneath the cooktop.
The Manufacturer declines any
liability if the accident-prevention
regulations are not respected.
Ensure that the hob supply cord
does not come into contact with
surfaces with temperatures higher
than 50 deg. C.
The replacement of electric
cable must be carried out
exclusively by the service for-
ce centre or by personnel with
similar competencies, in
accordance with the current
regulations.
NeutralNeutral
NeutralNeutral
Neutral
Earth (yellow/green)Earth (yellow/green)
Earth (yellow/green)Earth (yellow/green)
Earth (yellow/green)