Zephyr ZVE-E36S Ventilation Hood User Manual


 
9
Installation - Ductless Recirculating
Ductless recirculating is intended for applications where an exhaust duct work is not possible to be installed.
When converted, the hood functions as a "purifying" hood rather than an exhaust hood. Fumes and exhaust from
cooking is drawn and ltered by a set of optional charcoal lters. The air is then puried and re-circulated back within
the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct work, if
possible. The hood is most eective and ecient as an Exhaust unit. Only when the exhaust option is not possible
should you recourse to converting the hood into a "purifying"unit.
When converted to be a "purifying" unit, a set of charcoal lters are required on top of its standard Metal Filter set.
Order according to its Part number below. The standard Metal Filters are intended to capture residue from cooking
and the optional charcoal lters help to purify fumes exhausted from cooking for re-circulation.
RECIRCULATING KIT (Required)
Hood Model: Part No. Filters in pkg.
1. Kit includes charcoal lters and air diverter plate:
ZVE-E30S ZRC-0050 2
ZVE-E36S ZRC-0051 3
ZVE-E42S ZRC-0051 3
Ducting
2. Remove metal lters on hood. Clip chacoal
lters onto difuser panels.
3. Re-install metal lters.
4. Turn on lter change indicator on control
panel (refer details pg. 7)
5. Charcoal lters must be replaced after
every 120 hours of use (or approximately
every 2 to 3 months based on the average
of 1-2 hrs. of daily cooking time). The
microprocessor in the controls when set,
will elapsed and count usage time and
indicate when carbon lter replacement is
required every 120 hrs.
1. Install a 6" straight pipe attached to the air diverter
plate to divert air through louvers on duct cover.
6" straight pipe
wall pipe strap
air diverter
plate
Charcoal Filter Dimensions:
9 in x 6.4 in
228 mm x 162 mm