Zephyr ZVE-E30S Ventilation Hood User Manual


 
www.zephyronline.com
8
-noitallatsnI revoCtcuD&dooHehtgnitnuoM
1. Measure from range top to hood bottom
(28” min) Level and mark line A.
2. Plum and mark center line.
3. Mark mounting height line B. (10-3/8” from line A)
4. Mark mounting spread from C/L (9-7/16”)
5. Fasten E-Z anchors to wall (see below) as marked.
6. Fasten screws provided onto EZ anchors, do not
fasten screws all the way.
7. Hang hood onto screws and hand tighten (g A).
MOUNTING THE DUCT COVER
1. Center and attach duct cover mount bracket on
wall below ceiling or sot.
2. Mount telescopic duct covers onto hood and
extend inner duct cover and fasten to bracket.
EZ ANCHORS
A
B
C/L
10-3/8"
Du c t Cov er Brac ket
9-7/16"
C/L
28" min
fig. A
Tap EZ anchor tip into marked drywall locations, turn with screw-
driver until seated ush.
Note:whenever possible, the hood should be secured to wall studs.
Use EZ anchors only on hollow drywall applications (minimum
drywall thickness 1/2”). If a stud or wood surface is present,
fasten screws directly into stud or plywood. For all other wall types
(concrete, brick, tiles, etc), use appropriate anchors for mounting.