Operation / Data Log
332305B 39
Operation / Data Log
During operation the G3 Pump stores information as
Log and Summary Files.
Logs contain the following information:
Log Name
DMS ID Number
Current Software Graco Part Number
Current Software Version
Date and Time of Upload
System Event Log
The System Event Log lists the date and time of the last
800 common system events such as pump cycles, man-
ual run and setting changes. The most recent event is
listed first.
The log file is stored in a folder structure created by the
pump DMS ID and download date. If multiple downloads
are done on the same date, the existing files will be writ-
ten over.
The folder structure is as follows:
GRACO/G3_{DMS_id}/{download date - YYYYm-
mDD}/EVENTLOG.CSV
Example: GRACO/G3_00025/20100911/EVENT-
LOG.CSV.
Sample System Event Log
Example Event Log 1: Pump cycle of a divider valve
system with a proximity switch set to detect 5 divider
valve cycles.
G3 System Event Log
DMS ID Number: 0025 (see page 38)
Software Part Number: 16F821
Software Version: 1019
09/29/2010 14:1400
Date Time Description
9/29/2010 14:13:02 Pump Run Off
9/29/2010 14:13:02 C1 Cycle Completed
9/29/2010 14:12:39 C1 Cycle Detected
9/29/2010 14:12:34 C1 Cycle Detected
9/29/2010 14:12:28 C1 Cycle Detected
9/29/2010 14:12:23 C1 Cycle Detected
9/29/2010 14:12:17 Pump Run On