Run Mode
332305B 55
Additional Controls
Venting
In Max models a Vent Time can be set using the
Advanced Programming mode (page 47). This is typi-
cally done in a Pressure Based System (P1) to allow
injectors to reset.
• Unit vents for a set amount of time (not dis-
played).
• The LED’s next to C/P1, C/P2, C/P3 flash while
unit is venting.
• If Machine Count is set, the display will alternate
between machine counts remaining and backup
time (Max Model Rest Mode, page 53).
• If Machine Count has been set the LED next to
1-2-3 illuminates (F
IG. 34, page 54).
• If Machine Count has not been set the display
shows OFF Time (See Time Control, page 51).
• If Machine Count has not been set the LED next
to the clock in the OFF field illuminates (See
Time Control, page 51).
Prelube / Prelube Delay
In all models a power OFF/ON cycle can be controlled
with the Prelube and Prelube Delay functions.
Prelube
The Prelube function has been selected. Prelube delay
is set to 00:00:
• Power to the unit cycles OFF then ON.
• Unit immediately begins a lubrication cycle.
• Max Model - display shows Cycle/Pres-
sure/Backup Time (See Max Model Lubrication
Mode Controls, page 52).
Prelube Delay
The Prelube function has been selected. Prelube delay
is set to something other than 00:00:
• Power to the unit cycles OFF then ON.
• Unit immediately begins the Prelube Delay
count down until the lubrication cycle begins.
• The LED next to the clock in the OFF field is illu-
minated (F
IG. 36).
• The Prelube LED lights (F
IG. 36).
• The display shows time remaining until lubrica-
tion cycle begins. The example shown in F
IG. 36
shows 8 minutes and 14 seconds left until a
lubrication cycle begins.
F
IG. 36
ON
OFF
!
1 23
HH MM
SS ##
MM : SS HH : MM
2
3
1
P
C
C
P
C
P
C
P