9
*Note:
A chimney approved to ULC standard S629 in Canada or UL 103HT in the U.S. must be used to connect the smokepipe
at the top of the cabinet to maintain the 2" clearance to combustibles. The approved chimney must extend 1" below the heatshield.
PLEASE NOTE: That these are factory recommended clearances only, and are subject to local, provincial or state building and
fire codes. These clearances may change without notice
Chart of Clearances
Status Model A B C D E F G H J Measure
NO HEAT
SHIELD
SweetHeart
25 69 66 66 50 58 132 61 121 Centimeters
10 27 26 26 20 23 52 24 48 Inches
Oval
25 68 66 91 50 86 132 61 121 Centimeters
10 27 26 36 20 34 52 24 48 Inches
WITH HEAT
SHIELD
SweetHeart
25 8 61 61 5 31 132 61 121 Centimeters
10 3 24 24 2 12½ 52 24 48 Inches
Oval
25 8 61 91 5 44 132 61 121 Centimeters
10 3 24 36 2 17½ 52 24 48 Inches
When a heat shield is installed dimensions B, D, E and F are taken from the
heat shield.
Dimensions A, C, G, and H remain the same with or with-out a heat shield.
Dimensions A and C are taken from the
reservoir
on reservoir models.
When two or more clerances to combustible walls contradict each other,
the clearance with the greater numerical value must be maintained.