A SERVICE OF

logo

14
166240008
3/17/95
DUMP CYCLE
ADJUST HERE
SUPPORT WEB
FLOATASSEMBLY
RESERVOIR
WATER LEVEL
1/4
ILL023
1. With the proper water level in the water pan, start the water pump to circulate the water. Check that the
float will return water level to original setting and stop inlet water.
2. Push the manual dump switch -- allow dump action to drain the water pan. When you release the momen-
tary switch, the pump will stop and the float will return the water level back to its original setting and shut off
the water supply.
3. You have the option of selecting dump cycle intervals of:
S every cycle; (Standard setting from factory)
S every 3rd cycle;
S every 5th cycle;
S every 7th cycle.
Remember, the higher the mineral content in the water supply the more often it will be required to dump the wa-
ter and/or clean the product if proper water treatment is not used.
YL
YL
RH Evap.
Water
Dump
Valve
Contactor
Water
Pump
1
3
5
7
2
4
230v
115v
Voltage
Selector
Switch
GR
LH Evap.
Condenser
plug
Suction plug
Test
Plug
Options
Plug
Adjustable Ice
Thickness Pot.
Micro Processor
Stacking
Cable
Plug
Manual
Harvest
Switch
Transformer
To Stacked
Unit
(if re-
q
u
i
r
e
d
)
Fan
GR
RD
Error
Condenser Sensor
Suction Line Sensor
RH Evap. Switch
LH Evap. Switch
6
8
neutral
Dump
Every
Cycle
Dump
Every
3rd
Cycle
Dump
Every
5th
Cycle
Dump
Every
7th
Cycle
Sleeve Connector
Options Plug
D-15
D-13
D-14
D-12
D-10
Hot Gas
D-11
D-6
D-5
White
Brown