TYPICAL INSTALLATION: ALL ELECTRICAL & PLUMBING
MUST BE DONE PER LOCAL CODES.
NOTE: TAKE CARE NOT TO
KINK OR COLLAPSE VINYL
TUBING.
VENT
CONDENSATION
DRAIN
CONDENSER
DRAIN WC
OPEN TRAPPED OR VENTED
DRAIN
BIN
DRAIN
VENT
DRAIN
PIPE
WATER SUPPLY WC CONDENS-
ER
SERVICE VALVES
50 PSI MAX. WATER PRESSURE
STRAINER WATER
(NON-DIRECTIONAL)
WATER SUPPLY ICE MAKING
DUMP VALVE
DRAIN
DRAIN
Provide a suitable trapped open drain as close as possible to the area where the ice maker is going to be
installed. This may be an existing floor or a 1--1/4 trapped open drain. Two separate drain lines are required for
air cooled units, one for the storage bin and one for the dump valve drain hose.
An additional separate drain line will be required for water cooled units from the outlet of the condenser coil to
the drain. Run all gravity drain lines with a good fall to the open drain.
All Plumbing Must Be Installed In Accordance With Local Codes.
NOTE: In some cases it may be necessary to insulate the water supply line and drain line. Condensate
dripping to the floor can cause serious staining of carpets or hardwoods.
DRAIN CONNECTION INSTALLATION INSTRUCTIONS.
Taking care not to kink or collapse vinyl tubing at any point, route tubes to any open, trapped or vented floor
drain. Run tubing to drain separately. Do not tee any drain hoses together. Add drain tubing required to reach
floor drain.
WATER LEVEL RESERVOIR
The Float Valve is mounted in a fixed position thru its mounting bracket to maintain the proper water level in the
water reservoir. For the 300 & 322 series units the bracket is mounted thru the bottom hole of the bracket.