34 A-61557 December 2006
MICR recognition Recognition algorithm for E13B, CMC7 or CMC0 standards performed by the API
MICR data transmission Analog waveform through the USB port
Temperature Operating: 60 - 90°F (15 - 32°C)
Storage: 32 - 104°F (0 - 40°C)
Humidity 35 to 85% non-condensing
Scanner Dimensions Height: 6.8 in. / 17.3 cm
Length: 11 in. / 27.9 cm
Depth: 5.1 in. / 12.9 cm
Weight: 5 lbs. / 2.3 kg
Footprint: 5.1 in. / 12.9 cm x 8 6 in. / 21.8 cm
Acoustic Noise
(Sound Power level)
56 Lpa (dbA) peak @ the operator position
Electrical requirements Power Consumption: 50 watts (maximum)
115 Vac ± 10% 60 Hz
230 Vac ± 10% 50 Hz
Agency approvals UL, CUL, FCC, Class A, CE, EN55022 Class A
Product life 5,000,000 checks
Duty cycle
i6060 or i6090 Check Scanner
3,000 to 5,000 checks per day
MTTR (Mean time to repair) 20 minutes
Optional Printer Endorse back side of document prior to capturing the scanned image
12 nozzle printing resolution (96 dpi)
Cartridge: Hewlett Packard 6602A (up to 7,000,000 characters)