SECTION 1 – INSTALLATION
2
STEP 1: Preparing your pool and filtration system
IMPORTANT
The filtration system must be operating at its MAXIMUM WATER FLOW
before you install your ZODIAC G4™, otherwise you will have to re-adjust
your ZODIAC G4™ after cleaning the pool filter.
Installation is easy if you follow these simple preliminary steps:
1. Empty the weir basket.
2. Clean the pump basket.
3. Backwash the filter until the sight glass is clear.
4. Adjust all return jets (whether your pool has one, two or more) to point
downwards and towards each other so that you DO NOT see a circular
water flow or waves on the surface of your pool.
STEP 2: Assembling the Disc to your G4™
1. Viewed from underneath the unit, the fins on the Disc should point away
from you..
2. Beginning at one corner of the flat front section of the FlexiFoot, stretch the
Disc around to the other corner, until the Disc is held in place by the FlexiFoot.
3. The Disc should rotate freely once installed.
Diagram 1
Disc
Diagram 2
Unit with Disc fitted
(viewed from side)
Pull Disc under edge of FlexiFoot.
NB: Disc should locate
under pillar.