Aga Ranges AFHR-36 Refrigerator User Manual


 
Use & Care Guide
23
System Specification and Performance Data Sheet
Refrigerator Water Filter Cartridge Model UKF8001AXX
Specifications
Service Flow Rate (Maximum) 0.78 GPM (2 9 L/min)
Rated Service Life UKF8001AXX-750 (Maximum) 750 gallons/2839 liters
Maximum Operating Temperature 100° F / 38° C
Minimum Pressure Requirement 35 psi /241 kPA
Minimum Operating Temperature 33° F/1° C
Maximum Operating Pressure 100 psi / 689 kPA
PentaPure Inc.
1000 Apollo Road
Eagan, Minnesota 55121-2240
651 450 4913
EPA EST #35917-MN-1
100834/B
* Tested using a flow rate of 0.78 gpm; pressure of 60 psig;
pH of 7.5 + 0.5; temp. of 68° + 5° F (20° + 3° C)
** Measurement in Particles /ml. Particles used were 0.5 -
1 microns
*** NTU - Nephelometric Turbidity Units
General Use Conditions
Read this Performance Data Sheet and com-
pare the capabilities of this unit with your actual
water treatment needs.
DO NOT use this product where water is
microbiologically unsafe or of unknown
quality without adequate disinfection before
or after the system. System certified for cyst
reduction may be used on disinfected water
that may contain filterable cysts.
USE ONLY WITH COLD WATER SUPPLY.
CHECK FOR COMPLIANCE WITH THE
STATE AND LOCAL LAWS AND REGULA-
TIONS.
Tested and certified by NSF International against ANSI/NSF Standards
42 & 53 in models UKF8001AXX-750 for the reduction of:
The PuriClean® II retractable water filtration system uses a
UKF8001AXX replacement cartridge. Timely replacement of filter
cartridge is essential for performance satisfaction from this filtra-
tion system.
Please refer to the applicable section of your Use & Care Guide
for general operation, maintenance requirements and trou-
bleshooting.
This system has been tested according to ANSI/NSF 42 and 53
for reduction of the substance listed above. The concentration of
the indicated substances in water entering the system was
reduced to a concentration less than or equal to the permissible
limit for water leaving the system, as specified in ANSI/NSF 42
and 53.
Standard No. 42: Aesthetic Effects
Taste and Odor Reduction
Chlorine Taste & Odor
Mechanical Filtration Unit
Particulate Reduction Class 1
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead, Atrazine, Lindane, Mercury &
Toxaphene Reduction
Mechanical Filtration Unit
Cyst, Turbidity and Asbestos
reduction