15
SERVICING - WARNING
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
Ratings
Natural Gas Propane Gas
Cooktop
Orifi ce Screw Orifi ce Screw
Wok burner 15,000Btu/hr
internal 110
82 15,000Btu/hr
internal 71
49
external 166 external 93
Large Burner 12,000Btu/hr 170 70 12,000Btu/hr 106 38
Medium Burners 9,200Btu/hr 150 53 8,000Btu/hr 84 31
Small Burner 5,000Btu/hr 107 43 4,200Btu/hr 61 22
Gas burner inputs based on Gross Calorifi c Value
Ovens
Left hand Multifunction Oven Right hand Fan Oven
Fan element 2.5kW 2.5kW
Top element 1.2kW
Browning Element 1.15kW
Bottom element 1.0kW
Broiler
2.3kW
Maximum total electrical load at 240V 7.4kW (approximate total including oven lights, oven fan etc.)
Orifices
A Wok burner
B Large Burner
C Medium Burners
D Small Burner
A valve bypass screw