Alto-Shaam ASC-4G Convection Oven User Manual


 
Gas Convection Oven - Manual Control
Pg. 7.
GAS SUPPLY & INSTALLATION
GAS CONNECTION
FOR OVENS ON CASTERS
The oven must be supplied with a flexible
connector that complies with The Standard for
Connectors for Movable Gas Appliances, ANSI
Z21.69, CGA 6.16 and addenda Z21.69a (latest
editions). A quick disconnect device must be
installed to comply with The Standard for Quick
Disconnect Devices for Use with Gas Fuel, ANSI
Z21.41 and CAN1-6.9 (latest editions). A flexible
connector is not supplied by the factory.
Adequate means must be
provided to limit the
movement of the
appliance. Limitation of
movement must be made
without depending on the
connector, the quick
disconnect device, nor the
associated piping designed
to limit oven movement.
Mounting holes for a
restraining device are
located on the lower back
flange of the oven chassis.
Shut the gas supply OFF if it becomes
necessar y to disconnect the restraint.
Reconnect the restraint immediately
following the retur n of the oven to its
original position. Turn the gas supply ON
after the restraint has been reconnected.
LEAK TESTING
Use a soap and water solution on all gas supply
line connections.
CORRECT
RESTRAINT
D A N G E R
NEVER USE AN OPEN
FLAME TO LEAK TEST.