Alto-Shaam QC2-100 Freezer User Manual


 
QUICKCHILLER • INSTALLATION/OPERATION/SERVICE MANUAL • 4.
INSTALLATION REQUIREMENTS
The model QC2-3 is a counter mounted unit and
must use legs that allow for a 4" (102mm) clearance
between the cabinet and the counter.
For all other
models, install
the appliance
on a smooth and level
floor surface. Use the adjustable cabinet legs
to level the Quickchiller.
Adjust from front-to-back and from side-to-side
with the use of a spirit level to evenly distribute
the cabinet weight and avoid pulling the cabinet
alignment out of square.
After leveling the cabinet, check that the door
handle is aligned properly. Also check the height
relationship of the optional roll-in cart to the
cabinet. Adjust the Quickchiller height as needed
to accommodate the cart and to securely close the
Quickchiller door.
DOOR SEAL:
Check the door gasket to make certain it is sealing
properly and that the gasket provides an even and
positive seal around the entire door frame.
WATER DRAINAGE
A 1/2" I.D. (12,7mm) PVC pipe is furnished with
the QC2-100 model. Use PVC glue to attach the
pipe into the drain opening at the rear of the unit.
Insert the PVC pipe into the drain opening with
a 1/4" (6mm) clockwise turn. Connect the PVC
pipe to discharge through an indirect waste pipe
into an open-site drain by means of a 2" (51mm)
air gap. Connection must be within 10' (3m) of the
unit.
NOTE: In the U.S.A., this equipment is to be
installed to comply with the Basic Plumbing
Code of the Building Officials and Co de
Administrators International, Inc. [BOCA],
and the Food Service Sanitation Manual of
the Food & Drug Administration [FDA].
DRAINAGE:
QC2-3 QC2-20 QC2-40

QC2-100

1/2
caution
TO PREVENT PERSONAL INJURY,
USE CAUTION WHEN MOVING OR
LEVELING THIS APPLIANCE.
INSTALLATION
SITE INSTALLATION
40-7/8"
(1036mm)
14" (355mm)
Electrical
Connection
Condensate
Drain
51" (1294mm)
93-5/8" (2377mm)
35-1/2"
(902mm)
40" (1015mm)
75-1/2" (1917mm)
77-5/8" (1970mm)
8" (203mm) Condensate Drain
ALTO SHAAM
Electrical Connection
19-5/8"
(498mm)
QC2-100