Amana IC4 Refrigerator User Manual


 
4
10. Replace upper vertical cover by placing cover on
refrigerator. Carefully tuck wires inside cover to avoid
pinching wires. Insert and tighten screws with a
1
/4"
hex nut driver.
11. Remove tape from end of copper tubing. Put end of
copper tubing into sink or bucket. Slightly turn on
water supply to refrigerator. Water will be under
considerable pressure. Allow water to run through
copper tubing for 1 minute to flush out copper tubing.
Shut off water supply to refrigerator when flushing is
complete.
12. Slide nut and sleeve over end of copper tubing. Insert
copper tubing completely into adapter fitting. Check
adapter fitting to confirm rubber hose washer is in
place. Tighten adapter fitting by hand as much as
possible. Carefully tighten an additional
3
/8" (10 mm)
turn with pliers. Firmly connect tubing nut on copper
tubing to adapter fitting with two
1
/2" open-end
wrenches. Confirm copper tubing is secure by pulling
on copper tubing.
A
B
C
D
A. Hose washer B. Adaptor fitting
C. Sleeve D. Nut
Connecting copper tubing
13. Slightly turn on water supply to refrigerator and
check for leaks. Turn off water supply to refrigerator
and correct any leaks. Repeat this process until no
leaks are found. Completely turn on water supply to
refrigerator.
14. Slide ice service rack in freezer toward front of freezer
until screws are in middle of mounting holes. Gently
pull ice service rack away from freezer. Remove ice
service rack screws with a
1
/4" hex nut driver. Insert
plugs into screw holes.
15. Push up on lock tab to release water fill tube cover on
rear wall. Pull lower end of water fill tube cover away
from rear wall. Lift up slightly to release water fill tube
cover from upper hinges. Remove and discard water
fill tube cover.
16. Remove top freezer shelf.
17. Remove 3 screws from white air duct cover on rear
wall with a
1
/4" hex nut driver. Remove electrical cap
on rear wall with a screwdriver. Discard screws and
electrical cap.
18. Slide water fill tube extension over water inlet tube on
rear wall. Water fill tube extension must fit tightly and
be even with hole in rear wall so water cannot leak
into freezer.
A
A. Water inlet tube
Water inlet tube installation
19. Remove ice maker from shipping carton. Discard
packing material. Ice maker is shipped with arm
down. This is correct for ice production. Do not force
ice maker arm down or up.
20. Slide stainless steel clip over rear wall of ice maker
water cup.
A
B
A. Stainless steel clip B. Water cup
Stainless steel clip installation
21. Start two
5
/8" (16 mm) long sheet metal screws in top
holes on rear wall with a
1
/4" hex nut driver. Leave
heads out approximately
3
/8" (10 mm).
22. Hold ice maker in position. Ice maker can only be
installed one way. Do not drill additional holes. Insert
wire harness plug into receptacle on rear wall. Slide
ice maker hangers over sheet metal screws. Ease
water cup toward end of water fill tube extension.
Water fill tube extension fits under stainless steel
clip. Water fill tube extension must not be kinked.
Water fill tube extension should extend approximately
3
/8" (10 mm) into ice maker water cup and must be
secured under stainless steel clip.
Ice maker Installation
23. Install remaining
5
/8” (16 mm) long sheet metal screw
under ice maker and tighten all 3 screws with a
1